• Using the digital MTR as the word clock master
In this case, the digital MTR will be the word
clock master, and the AW2816 will follow the
word clock included in the input signal from the
digital I/O card. Turn on one of the SLOT 1/2–7/8
buttons.
OPTION
I/O SLOT
AW2816
Digital I/O card
(word clock slave)
WORD CLOCK SOURCE
= SLOT 1/2–7/8
Set the digital MTR so that it will operate using its
own internal clock.
• Using a DAT recorder or MD recorder as the
word clock master
If you want to record the signal from a DAT
recorder or MD recorder into the AW2816 via
the DIGITAL STEREO IN jack, turn on the D.ST
IN button.
DIGITAL
Word clock
STEREO IN
jack
AW2816
DIGITAL
(word clock slave)
STEREO OUT
jack
WORD CLOCK SOURCE
= D.ST IN
Most consumer DAT recorders and MD recorders are
designed to forcibly lock to the word clock of the
input signal during recording. Such DAT recorders
can be used as a word clock master only during play-
back.
Word clock
Digital MTR
(word clock master)
DAT
00.00.00.00
DAT recorder
(word clock master)
Operation section
3
After selecting the appropriate button,
press the [ENTER] key.
The AW2816 will switch to the specified clock
source. The sampling frequency of the signal cur-
rently selected as the clock source will be indi-
cated by the Fs (sampling frequency) field in the
upper left of the display.
• If you are using the internal clock of the AW2816 as
the clock source, the sampling frequency selected
when you created the current song will be the sam-
pling frequency of the entire system.
• If you want the AW2816 to follow an external clock
source, you must make sure that the sampling fre-
quency of the song matches the value displayed in
the Fs field. If these values are different, the pitch
may change when you set the clock source back to
"INT" (internal clock).
• A certain amount of time may be required for the
AW2816 to switch clock sources, and there may be
silence during this time.
• After switching the clock source, verify that an X or/
symbol is not superimposed on the button you
selected in step 3. If an X or/symbol is displayed, or
if an error message is displayed, check whether the
clock setting and connections of the external device
is appropriate.