(8) If any of the conditions in "(4)-ii" and "iii", repeat the assembling procedure from Step
4.21.1.3.
(9) When the adjustment and check are completed, fix the two locations on the support
using a clamping band.

4.21.1.5. Data Input

Note:
Enter the attached minimum value data in the light receiver.
The following two data parameters are entered.
(1) Camera Magnification X 0000 (four digit numbers)
(2) Camera Magnification Y 0000 (four digit numbers)
* Do not change the values for X[ ], Y[ ].
(1) Select " Sys. Setting " , " Offset " . " Device Offset (P2/2) " and " Line Meas " in this order.
(2) Change the values for " Magnification X " and " Magnification Y " for the head where
the light receiver has been changed, to the data values included in the light receiver.
(3) Save the changed values.
Service Information
Binding at the lower end
Fig.D130
Fig.D131
SI1705004E-00=SIGMA-G5SII Service Manual