Cleaning The Retainer (35) Assembly - Sony FVS-1000 Maintenance Manual

Multi resolution film scanner
Hide thumbs Also See for FVS-1000:
Table of Contents

Advertisement

3-2. Cleaning the Running System

3-2-2. Cleaning the Retainer (35) Assembly

Removing
1. Set a unit in the STANDBY OFF mode.
2. Turn off the power.
3. Pull out the OPS cover toward you.
4. Release the two one-touch fixing screws with turning
90 degrees counterclockwise, pull the retainer (35)
assembly in the direction of arrow, then remove it
from the guide pin.
One–touch fixing screws
Guide pin
Retainer (35)
assembly
3-4
5. Remove the adherence with air etc.
6. Clean the portion contacting the gate on the GND
7. Wipe the cleaned surface with a dry cloth two or three
8. Confirm that the GND terminals and film pads can
Installing
9. Install the retainer (35) assembly in the reverse order
Guide pin
terminals, the portion contacting the film on the film
pad and film guides with a cleaning cloth to which the
cleaning fluid is applied.
times.
Film guide
GND terminal
Clean
move smoothly up and down.
of removing procedure 1 to 4.
[Reference]
When the groove (_) of the one-touch fixing screw is
almost horizontal, the assembly is fixed.
Film pad
GND terminal
Film guide
FVS-1000 MMP1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvs-t1000Fvs-p1000Bkfv-100Bkfv-200

Table of Contents