HP 81200 User Manual page 236

Data generator/analyzer platform
Hide thumbs Also See for HP 81200:
Table of Contents

Advertisement

How Do I ... ?
236
Clock
RZ Signal at channel 2
Delayed
RZ signal at channel 1
Added signal
Figure 146
Addition of two RZ Signals
To capture (and analyze) such a signal:
If your analyzer frontend can make it, you can capture the signal with
twice the generator frequency (and 50 % delay).
If not, you may be able to set up two analyzer channels, operating at the
generator frequency. In this case, the first analyzer should be set to 25 %
delay and the second to 75 % delay.
HP 81200 Data Generator/Analyzer Platform User Guide, Revision 2.1
How Can I Create and Capture a Double-Speed PRWS?