11.1.7.

Delete the command line

Operation of deleting the line of code or the position variable is shown.
1) Select the line to delete or the position variable. Two or more lines can be selected. (<a>)
<b>
2) Tap the [Delete] button (<b>), the selected line of code or the position variable will be deleted.
It becomes the error when it is going to delete the position variable currently used by the line of code while
editing the program of the robot controller. Push the [RESET] button of T/B. Since the message of
confirmation is displayed, tap the [OK] button. (<c>)
<a>
42
<a>
<b>
<c>