Connection
(3)Connection mode configuration
■Configuration software IOT_CONFIG use
The configuration software IOT_CONFIG is a special software used to configure the external connection function of
this product. It can be run on a PC with Windows XP and above operating systems. The interface after installation
and operation is as follows:
The operation steps for setting welding machine parameters through software are as follows
【1】 Connect the RS232 serial port to the welding machine
【2】 Click Set detection port, set the baud rate (default is 19200) and open the serial port
【3】 Click connect and read configuration, read welding machine parameters
【4】 Click to download configuration to IOT to configure welding machine parameters
【5】 Restart the welder
The IOT_CONFIG software is as follows, copy it to use.
IOT_CONFIG.exe
The specific operation process is shown in the figure below: