(2) As shown in the figure below, use a cross screwdriver to remove the four screws connecting the welding power
supply and the liquid cooling system. After removing the screws, pull up the handle to separate the welding power
supply from the liquid cooling system. Before independent use of welding power supply, please pay attention to
short circuit the temporary stop 2 of terminal block P. please refer to sections 8.1 and 8.2 for the location of terminal
block P. If you need to install casters for the disassembled welding power supply, please order from Tangshan
Panasonic agent, caster model: 2-3688-52
Rubber cover: SG30AK (two)
Note: Do not discard the cover after
disassembly
Please install the cover when
assembling
(3) When installing the liquid cooling system, please refer to the disassembly diagram and install in reverse
order