Electric installation

10.7.1 Connecting the display to the 24 V voltage supply

Connect the "X1S1" interface for the 24 V voltage supply to the industrial power supply unit.
For the voltage supply, use a 24 V industrial power supply unit acc. to DIN EN 60742, classifica-
tion VDE 551, for example "VAP01.1H-W23-024-010-NN" (part number R911171065).
UPS
The display immediately darkens in case of a power failure if the operator display is directly
connected to the 24 V supply voltage without UPS. The user cannot execute any actions via the
operator display during the shutdown of the control cabinet PC.
If the operator display is connected together with the control cabinet PC to the "24 V Out" of
the external UPS (VAU 02.1), the user can still access the operator display during shutdown
due to a power failure.

10.7.2 Connecting the control cabinet PC to operator display

Exemplary connection diagram of a CDI+ display connection.
Control cabinet PC
Functional earth
Fig. 26: Wiring the control cabinet PC to the operating display
Connection
1.
Connect the functional earth.
2.
Connect the XCDI+tx interface at the control cabinet PC to the XCDi+rx interface at the respec-
tive operating display using a CDI+ cable.
R911405731, Edition 03
XCDI+tx
Electric installation
Operating display
XCDI+rx
Bosch Rexroth AG
35 / 52