ctrlX HMI DE0015, DE0021
7.3
Optical characteristic values
7.3.1
TFT
The maximum permissible number and type of pixel errors of TFT displays depends on the manufac-
turer and is defined by the respective incoming inspection of the vendor.
7.3.2
Input system or multi-touch front
The maximum permissible number, type and size of defects on the front, on the glass or between the
display and the front – such as trapped dust, dirt and scratches is defined in the FT quality guideline.
8
Standards
8.1
Standards used: E-STOP button
Standard
The E-STOP button is identified as safety component according to machinery directive 2006/42/EC
(annex V-10, E-STOP devices) by the vendor. The compliance with the directive is proven by adherence
to the following European standards:
IEC 60947-1
IEC 60947-5-1
IEC 60947-5-5
ISO13849-1
IEC 13850
8.2
CE marking
8.2.1
Declaration of conformity
The electronic products described in these instructions comply with the requirements and the target of
the following EU directive and the following harmonized European standards:
EMC directive 2014/30/EU
The electronic products described in the present instructions are intended for use in industrial environ-
ments and comply with the following requirements:
R911405731, Edition 03
Meaning
Low-voltage switchgear and controlgear – Part 1: General rules
Low-voltage switchgear and controlgear – Part 5-1: Control circuit
devices and switching elements – Electromechanical control cir-
cuit devices
Low-voltage switchgear and controlgear - Part 5-5: Control circuit
devices and switching elements - Electrical emergency stop device
with mechanical latching function
Safety of machinery – Safety-related parts of control systems –
Part 1: General principles for design
Safety of machinery — Emergency stop function — Principles for
design
15 / 52
CE marking
Bosch Rexroth AG