32 / 52
Dismounting
Fig. 22: Tightening the support arm during
6
Connect all cables.
7
Tighten the housing cover with the six M3 screws.
10.4
Installation notes
•
When mounting the display, ensure an ergonomic operation. Additionally, ensure that all moving
machine components can be seen by the operator at any time
•
Avoid installation positions exposed to direct UV and sunlight. Direct sunlight reduces the reada-
bility at the screen and causes additional warming
•
The LED display on the operator panel must not be covered.
•
Wire all cables in loops. Use strain reliefs for all cables
•
To maintain the degree of protection IP 65, use only a cable bushing of the sealing gasket fitting to
the cable cross sections. If required, use the fitting sealing gasket
•
Do not lay the CDI cables in parallel to motor cables or to other noise sources, as the CDI
connection can be disturbed. Keep the maximum distance possible from interference sources
10.5
Dismounting
1.
Disconnect the operator display from voltage.
2.
Remove all connected cables.
3.
Loosen the screws at the support arm fixture.
4.
Remove the display from the support arm fixture.
Bosch Rexroth AG
hanging mounting
ctrlX HMI DE0015, DE0021
R911405731, Edition 03