Ambient Conditions; Technical Data - Bosch IndraControl PR21 Operating Instructions Manual

Table of Contents

Advertisement

6/29

Technical data

6 Ambient conditions

Humidity
Operating temperature
Storage and transport temperature -20 to 70 °C
Shock protection
Overvoltage category
Contamination level
Mechanical strength
Tab. 6-1: Ambient conditions
NOTICE
Due to the risk of corrosion, avoid sulphurous gases (e.g. sulphur dioxide (SO
and hydrogen suphide (H
NOTICE
Keep the device away from oils and emulsions.
NOTICE
The ambient air must not contain acids, alkaline solutions, corrosive agents,
salts, metal vapors and other electrically conductive contaminants in high
concentrations
The devices to be installed into the housing and installation compartments
must at least comply with the degree of protection IP 54 according to DIN EN
60529.
The device shall be provided in a suitable fire enclosure in the end-use appli-
cation.
7 Technical data
CPU
GPU
Memory
Bosch Rexroth AG R911389662_Edition 02
IndraControl PR21 Embedded Automa-
85% at 40°C (non-condensing)
0 to 50 °C
IEC 60068-2-27
2
2, no condensation allowed
IEC 60068-2-64, acceleration: 2G
Defective product due to gases jeopardizing
functions
S)). The product is not resistant against these gases.
2
Risk to damage the device due to external influ-
ences
Failure of the product due to contaminated air
PR2100
Intel Atom Single Core E3815
1.46 GHz
Intel® HD Graphics
Onboard 4G DDR3L, 1066 MHz RAM
tion Computer
)
2