Huawei FusionCol8000-E240 User Manual page 23

Modular indirect evaporative cooling system
Hide thumbs Also See for FusionCol8000-E240:
Table of Contents

Advertisement

FusionCol8000-E240 Modular Indirect Evaporative
Cooling System
User Manual
No.
1
2
3
4
5
6
Issue 01 (2021-01-30)
Item
Description
Air filter
● Indoor return air filter (side): G4 filters The air filter
matches the cleanliness requirements of different
equipment rooms, and meets the relevant requirements of
the China National Standard
● Outdoor intake air filter (end): G3 filters The air filter
matches the cleanliness requirements of different
equipment rooms, and meets the relevant requirements of
the China National Standard
● Outdoor intake air filter (side): G3 filters The air filter
matches the cleanliness requirements of different
equipment rooms, and meets the relevant requirements of
the China National Standard
Spray
● Wet film spraying for evaporative cooling lowers water
module
quality requirements and improves environmental
adaptability. The structure is simple and easy to
disassemble, clean, and maintain.
● Spray water is in direct contact with the spray module. The
spray module is periodically maintained to prevent the
core from scaling and corrosion.
Heat
● An efficient heat exchanger core is used. The heat
exchange
exchanger core adopts the innovative flow design, which
r core
improves efficiency and reduces air resistance.
● The heat exchanger core has high adaptability. It applies
to high-temperature, low-temperature, and high- and low-
temperature impact environments.
Condens
The condenser adopts the flow design with a low wind
er
resistance.
Exhaust
● A Huawei-developed high-speed fan is used, which
fan
features large air volume, high static pressure, high
reliability, and a long service life.
● The fan is separated from the drive. The fan efficiency is
improved by more than 8% compared with a common EC
fan.
● The direct drive that the fan adopts has higher
transmission efficiency than the belt drive, which reduces
belt replacement and routine checks.
Evaporat
The synergy field principle and computational fluid dynamics
or
(CFD) are used to optimize the flow path design, greatly
improving the heat exchange efficiency. The evaporator air
flow organization is more reasonable, and the air resistance
is smaller.
Copyright © Huawei Technologies Co., Ltd.
2 Product Description
GB/T 14295-2008 Air filters .
GB/T 14295-2008 Air filters .
GB/T 14295-2008 Air filters .
14

Advertisement

Table of Contents
loading

Table of Contents