4-5-5. D/A Video Level Adjustment

n
Turn on the main power of the MAV-555A and measuring equipment. Wait for at least 30 minutes
before starting any adjustments.
1. Select "D/A : Video Level" of the ADjuster2.
2. Press the R1 button of the PORT SELECT block on the meter panel.
3. Enter the R1 port into the record mode. (The internal SG signal (100% color bars) is recorded on the
R1 port.)
n
For details of the recording procedure, refer to the Operation Manual of the MAV-555A and that of
the control panel.
4. Press either the P1 or the P2, P3 button of the PORT SELECT block of the meter panel in accordance
with the port to be adjusted.
5. Select the material that is recorded in step 3. Enter the P1 (or P2, P3) port into the playing mode.
n
For details of the playback procedure, refer to the Operation Manual of the MAV-555A and that of
the control panel.
6. After the setup value of the level bar of the ADjuster2 has been set using the
mouse of a personal computer, click "Set" to check the level.
Set value
MAV-555A
4-5. ADA-61 Board (BKMA-513) Adjustment
and
keys, or
4-15 (E)