1-3. Backing Up and Restoring the Contents of Memory (FM-81 board)
Restoration procedure
1. Go to the MS-DOS prompt (or command prompt).
2. Enter the directory in which the back-up data is stored. (e.g.: cd\\temp)
3. Input [ftp 192.168.0.1] and press the [ENTER] key.
4. When prompted for the User ID, input [Glider] and press the [ENTER] key.
5. When prompted for the password, input [Grydar] and press the [ENTER] key.
6. When the FTP connection is completed and [ftp>] is displayed, input [binary] and press the [ENTER]
key to switch to the binary mode.
7. Input [put fmbackup.fs _SRAM_ALL] and press the [ENTER] key.
(Input the new backup file name in the underlined characters.)
8. Input [bye], press the [ENTER] key, and release the FTP connection.
9. Turn off the main power of the MAV-555A.
n
To restart quickly, execute [027-FAST REBOOT] of the set-up menu.
Example of screen
c:\> cd\\temp
c:\temp> ftp\192.168.0.1
Connected to 192.168.0.1
220 Welcome to 192.168.0.1
User (192.168.0.1 : (none)) : Glider
331 User name okay, need password.
Password : Grydar
230 Password okay.
ftp> binary
200 TYPE Command Okay!!
ftp> put\fm990725.fs\_SRAM_ALL
220 PORT Command Successful
150 Opening data connection for.
226 Transfer complete.
Please login with USER and PASS.
8388608 bytes sent in 17.08 seconds (491.14 Kbytes/sec)
ftp> bye
221 Good Bye See You