Code
Contents of error
00
All items normal finish
11
MR sensor
DC value.
Amplitude error
12
13
15
16
18
19
1A
1C
1D
1E
20
Reset sensor
.mechanism
termination
31
detects failure
32
33
34
35
36
37
41
Reset sensor
.mechanism
termination
42
position data
error
43
44
45
46
47
48
49
4A
50
EEPROM
60
error
70
HI communication error
2-30
Measuring time Time Up
Pan OK/Tilt DC value incorrect
Pan OK/Tilt amplitude is dissatisfied
Pan DC value incorrect/Tilt OK
Pan DC value incorrect/Tilt DC value incorrect
Pan DC value incorrect/Tilt amplitude is dissatisfied
Pan amplitude is dissatisfied/Tilt OK
Pan amplitude is dissatisfied/Tilt DC value incorrect
Pan amplitude is dissatisfied/Tilt amplitude is dissatisfied
Unsuccessfully adjustment
Max current sequence
Reset sensor abnormal
Measuring time Time Up
Pan
Movable range between mechanism termination
point distance is insufficient
Incorrect distance between left sensor and Home
position
Incorrect distance between left sensor and left
termination
Incorrect distance between right sensor and Home
position
Incorrect distance between right sensor and right
termination
Tilt
Movable range between mechanism termination
point distance is insufficient
Incorrect distance between bottom sensor and
Home position
Incorrect distance between bottom sensor and
bottom termination
Incorrect distance between top sensor and Home
position
Incorrect distance between top sensor and top
termination
Write failure
Read failure/Abnormal data
Table 2 Error Code Table of Pan and Tilt Adjustment
Possible cause
Pan
. Initial position is set incorrectly when
adjustment status
. Incorrect pan and tilt mechanism
Tilt
(friction or obstruction)
Both of Pan/Tilt
. Incorrect motor drive circuit
. Incorrect MR sensor
. Incorrect hole sensor
. Incorrect pan and tilt mechanism
(friction or obstruction)
. Abnormal torque supplied from out
Pan
side
Tilt
. Tilt motor is not fixed
Pan
. Sticking of FFC
. Reset sensor not connected
Tilt
Pan
Tilt
Both Pan/Tilt
. Incorrect pan and tilt mechanism
. Sticking of FFC
. Failure of reset sensor or reflection
board
. EEPROM failure
. EEPROM communication failure
. Failure of camera block connection