4. G-CAM flip Adjustment
Set the color reproduction conditions to optimum.
Subject
Not required
Measurement Point
Display data of page 1 of the
Measuring Instrument
adjusting remote commander (*)
Adjustment Page
F
Adjustment Address
21
Specified Value
S1 > S2
n
* : Displayed data of page 1 of the adjusting remote
commander.
1 : XX : XX
S2
S1
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 16.
3) Select page 1 of the adjusting remote commander, and
compare the higher 2 digits (S1) and lower 2 digits
(S2) of the 4-degits display data.
When S1 < S2
Perform steps 4) and after.
When S1 > S2
Perform steps 5) and after.
4) Select page: F, address: 21, set data: 52, and press the
PAUSE button of the adjusting remote commander.
Before Modify data
After Modified data
52
D2
5) Select page: 0, address: 03, and set data: 00.
6) Select page: 0, address: 01, and set data: 00.
2-18
D2
52
5. HALL Adjustment
For detecting the position of the lens iris, adjust the hall
AMP gain and offset.
Subject
Not required
Measurement Point
DDS display data of TV monitor (* 3)
Measuring Instrument
Adjustment Page
F
Adjustment Address
2F, 30
Specified Value
90 to 94 during IRIS OPEN (* 1)
19 to 1D during IRIS CLOSE (* 2)
m
* 1 : Select page: 2, address: 01, set data: 01, and press the
PAUSE button of the adjusting remote commander.
* 2 : Select page: 2, address: 01, set data: 03, and press the
PAUSE button of the adjusting remote commander.
* 3 : DDS display data of TV monitor.
00 00 XX
Object data
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 03.
3) Select page: D, address: 11, set data: 02, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 01, set data: 03, and press the
PAUSE button.
5) Select page: F, address: 30, set data: 80, and press the
PAUSE button.
6) Select page: F, address: 2F, set data: 40, and press the
PAUSE button.
7) Read the DDS display data (the bottom two digits of
the display data at the bottom right of the TV monitor),
and this data is named K
8) Select page: F, address: 2F, set data: 30, and press the
PAUSE button.
9) Read the DDS display data, and this data is named K
10) Select page: 2, address: 01, set data: 01, and press the
PAUSE button.
11) Read the DDS display data, and this data is named W
12) Select page: F, address: 2F, set data: 40, and press the
PAUSE button.
13) Read the DDS display data, and this data is named W
14) Convert W
, W
, K
, K
1
2
1
obtain W
' , W
' , K
' , K
1
2
1
"Hexadecimal notation - decimal notation conversion
table".)
.
2
, to decimal notation, and
2
'. (Refer to page 2-7
2
EVI-D100/EVI-D100P
.
1
.
1
.
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evi-d100cEvi-d100cpEvi-d100p

Table of Contents