Sony EVI-D100 Service Manual page 41

Color video camera
Hide thumbs Also See for EVI-D100:
Table of Contents

Advertisement

2. SYNC Level Adjustment (DD-161 board
(NTSC), DD-161P board (PAL))
Set the Y signal output level.
Subject
All black
Pin !- of CN501
Measurement Point
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
49
A = 286 ± 5 mV (NTSC)
Specified Value
A = 300 ± 5 mV (PAL)
NTSC Model:
EVI-D100/D100C
PAL Model:
EVI-D100P/D100CP
n
Terminate at 75 Z resistor and measure.
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 49, change the data and set the
SYNC level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote
commander.
4) Select page: 0, address: 01, and set data: 00.
H
EVI-D100/EVI-D100P
3. BURST Level Adjustment (DD-161 board
(NTSC), DD-161P board (PAL))
Set the chroma signal output level.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
NTSC Model:
PAL Model:
n
Terminate at 75 Z resistor and measure.
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 4B, change the data and set the
burst level (A) to the specified value.
3) Press the PAUSE button of the adjusting remote
commander.
4) Select page: 0, address: 01, and set data: 00.
A
All black
Pin !- of CN501
Oscilloscope
F
4B
A = 286 ± 5 mV (NTSC)
A = 300 ± 5 mV (PAL)
EVI-D100/D100C
EVI-D100P/D100CP
H
A
2-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evi-d100cEvi-d100cpEvi-d100p

Table of Contents