5. When the code type is data matrix/GS1 data matrix
Name
Omit
Object No.
X-position
Y-position
Rotation angle
Code type
Module height
Module width
Mode
Symbol size
(vertical)
Symbol size
(horizontal)
Human readable
text
Code marking
direction
Module marking
order
Total data length
* Setting request data are variable length.
*1 : Available combinations for the number of horizontal and vertical symbol modules (vertical X horizontal)
Auto
00×00
Square:
10×10, 12×12, 14×14, 16×16, 18×18, 20×20, 22×22, 24×24, 26×26,
32×32, 36×36, 40×40, 48×48, 52×52, 64×64, 72×72, 80×80, 88×88
Rectangle
08×18, 08×32, 12×26, 12×36, 16×36, 16×48
Data
length
[byte]
Max. 4*
"0000"–"1999"
Y
Max. 8*
"-999.999"–"+999.999" [mm]
Y
Max. 8*
Y
Max. 8*
"-180.000"–"+180.000" [°]
"20": Data matrix
(Y)
2
"21": GS1 data matrix
Y
Max. 5*
"0.001"–"9.999" [mm]
Y
Max. 5*
"0": One-byte mode
Y
1
"1": Kanji mode
Y
Max. 2*
"00", "08"–"88"
(Combination of vertical and
horizontal is limited *1)
Y
Max. 2*
"0": OFF
Y
1
"1": ON
"0": One-way direction
Y
1
"1": Alternate
"0": No skip
Y
1
"1": Skip one
"2": Skip two
Max. 60
It is the length including the separator ",".
Data contents
ME-LPGS-SR-5
Remarks
It is the center coordinate of the code.
The rotation center is the center of the
code symbol.
Specify "0" for GS1 data matrix.
• The number of characters that can
be input varies depending on the
symbol size.
• Specifying "00" for the symbol size
(both for horizontal and vertical)
encodes by the minimum size
(square).
When "Alternate" is selected, the
marking order inverts by module row or
column.
• The filling order for the module is
indicated. Select if you will mark
the modules next to each other
consecutively or skip the one next to
it.
• When on-the-fly marking is set, set
always "0": No skip.