3-6-5 Lot settings: LTC

Configures the "Lot" function used to change characters depending on the date/time and counter values.
⿎ Setting request data / response data for readout
Start
LTC
Sub command
code
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Readout request data
Start
LTC
code
⿎ Data description
Data
Name
length
[byte]
Lot No.
Max. 2*
Lot unit
Max. 2*
Lot type
Max. 2*
Total data
Max. 8
length
* Setting request data are variable length.
Reference
• When the lot unit of the lot settings (LTC command) is changed, the lot period and lot character (LTS command) settings
registered to that lot number are deleted.
⿎ Example of command settings
Condition:
Lot No. = 0, Lot unit = 8, Lot type = 0
• Setting
Transmission data
• Readout
Transmission data
Response data
[Lot No.]
R
Max. 2-byte
Data contents
"00"–"31"
"00": Year
"01": Month
"02": Day
"03": Year and month
"04": Month and date
"05": Day of the week
"06": Hour
"07": Week
"08": Minute
"09": Hour and minute
"10": Counter
"11": Year (week-based)
When the lot unit is "00" to "09" and "11"
"00": Current date/time
"01"–"32": Expiry time No.
When the lot unit is "10"
"00"–"31": Counter No.
It is the length including the separator ",".
[STX]
LTC
[STX]
LTC
[STX]
LTC
[Lot No.], [Lot unit],
[Lot type]
Max. 8-byte
(Check sum)
"16" to "31" are the global lot numbers.
It is the unit of period to switch lot
characters.
Specifies which function you are
referencing, the current date/time, expiry
date, or counter, to switch lot characters.
S
0,8,0
[CR]
R
0
[CR]
A
00,08,00
[CR]
ME-LPGS-SR-5
(Check sum)
End code