Transponder
7.10 SIMATIC RF622T
Permitted ambient conditions
Ambient temperature
Distance from metal
Degree of protection
Resistance to mechanical stress
Shock resistant to EN 60068-2-27
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (L x W x D)
Weight
In the current chip version of the transponder, the TID can be written to. It is not
1)
recommended that you use the TID as user memory.
The information relates to the maximum read range. You will find more information on
2)
ranges in the section "Minimum distances and maximum ranges (Page 293)".
The values for shock and vibration are maximum values and must not be applied
3)
continuously.
348
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
Transponder
Spacer
Transponder
Spacer
6GT2810-4HC80
-25 to +85 °C
-40 to +85 °C
-40 to +80 °C
Not suitable for mounting directly on metal
IP67
Torsion and bending stress is not permitted
100 g
3)
50 g
3)
120 × 30 × 6.5 mm
130 × 31.5 × 12 mm
14 g
8 g