NOTICE
Approved use
This device/system may only be used for the applications described in the catalog and the
technical documentation "System manual MOBY D, RF200, RF300, RF600
(https://support.industry.siemens.com/cs/ww/en/ps/14971/man) and only in combination
with third-party devices and components recommended and/or approved by Siemens.
7.8.3
Use of the transponder in hazardous areas
In a conformity declaration, TÜV NORD CERT GmbH has confirmed compliance with the
essential health and safety requirements relating to the design and construction of
equipment and protective systems intended for use in potentially explosive areas as per
Annex II of the directive 94/9/EG.
The essential health and safety requirements are satisfied in accordance with standards
EN 60079-0: 2009, EN 60079-11: 2007 and EN 61241-11: 2006.
This allows the RF610T special variant ATEX transponder to be used in hazardous areas for
gases, for the device category 3 G and gas group IIB, or alternatively in hazardous areas for
dusts, for the device category 3 D and group IIIB.
Identification
The identification is as follows:
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
II 3 G Ex ic IIB T6 to T4 or
7.8 SIMATIC RF610T ATEX
II 3 D Ex ic IIIB T120°C,
-25 °C < Ta < +85 °C
Transponder
333