Antennas
6.3 Antenna RF640A
Electrical data
Range
Impedance
Polarization
VSWR (standing wave ratio)
Power
Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
218
ETSI
FCC
During operation
During transportation and storage
See section "Maximum read/write ranges of
transponders (Page 297)"
50 Ω
Circular
≤ 1.25
≤ 1.6
2 W
30 cm coaxial cable with RTNC coupling (for
connection of the antenna cable)
PA 12
Pastel turquoise
≤ 2 Nm
-25 to +75 °C
-40 to +85 °C
IP65
25.5 g
2)
1g
2)
185 x 185 x 45 mm
600 g
CE (according to R&TTE), FCC (Title 47, Part
15.247), cULus
445 years