B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.12 NCU link with different interpolation cycles
Appropriate changes to parameter settings
A change in the parameter settings of machine data:
MD10065 $MN_POSCTRL_DESVAL_DELAY
is appropriate in the following cases:
● DSC is always activated or feedforward control is never activated for axis operation.
● With the typically used controller structure, there will be a delay in machine data:
2.12.3

Supplementary conditions

● The option "different interpolation cycle" can only be used in conjunction with NCU link
● It is only permissible to use link axes on NCUs whose IPO cycle length is the same as
194
In these cases, an additional delay is only necessary on the NCU with the fast position
control cycle. Here the following procedure is appropriate:
1.) MD32990 $MA_POSCTRL_DESVAL_DELAY_INFO[0] on any axis on the NCU with
the slowest position controller cycle.
2.) Subtract this time from the current value in machine data:
MD10065 $MN_POSCTRL_DESVAL_DELAY
on all NCUs.
MD32990 $MA_POSCTRL_DESVAL_DELAY_INFO
in the axis with the fast position control cycle; the delay is not an integer multiple of the
position control cycle.
As there are particularly high dynamic performance requirements on the axis with the fast
position control cycle, even the necessary averaging for generating the delay may lead to
problems.
Example: Typically, machining is conducted with speed feedforward control. In axis X of
NCU-U in the diagram "Schematic example of a configuration with several NCUs and
eccentric machining unit" (Section "Diagram of general solution"), a value of 7 ms is read
out in machine data:
MD32990 $MA_POSCTRL_DESVAL_DELAY_INFO[1]
The position control cycle on this NCU is 2 ms.
In this case it may be useful to increase the machine data below on all NCUs by 1 ms:
MD10065 $MN_POSCTRL_DESVAL_DELAY
The resulting value of 8 ms in MD32990 POSCTRL_DESVAL_DELAY_INFO[1] will then
be an integer multiple of the position control cycle of 2 ms.
(options, dependent on the axis number). The connected NCUs must all be fitted with the
link module hardware components.
– The configuration rules outlined in "Configuration of a link grouping" apply.
– Link axes must be configured as described in Section "Configuration of link axes".
– Axis containers can be used as described in Section "Axis container".
that of the link cycle,
Function Manual, 09/2009, 6FC5397-1BP20-0BA0