Signal name
Stop at next reversal point
Stop along braking ramp
PLC-controlled axis
12.6.3.2
Signals from axis/spindle
Signal name
Oscillation reversal is active
Oscillation cannot start
Error during oscillation movement
Sparking-out active
Oscillation movement active
Oscillation active
12.6.4
System variables
12.6.4.1
Main run variables for motion-synchronous actions
Main run variable_read
The following variables are provided for main run variable_read:
$A_IN[<arith. Expression>]
$A_OUT[<arith. Expression>]
$A_INA[<arith. Expression>]
$A_OUTA[<arith. Expression>]
$A_INCO[<arith. Expression>]
$AA_IW[<axial expression>]
$AA_IB[<axial expression>]
$AA_IM[<axial expression>]
$AA_OSCILL_BREAK_POS1
$AA_OSCILL_BREAK_POS2
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
SINUMERIK 840D sl
DB31, ... .DBX28.5
DB31, ... .DBX28.6
DB31, ... .DBX28.7
SINUMERIK 840D sl
DB31, ... .DBX100.2
DB31, ... .DBX100.3
DB31, ... .DBX100.4
DB31, ... .DBX100.5
DB31, ... .DBX100.6
DB31, ... .DBX100.7
Digital input (Boolean)
Digital output (Boolean)
Analog input (Boolean)
Analog output (Boolean)
Comparator inputs (Boolean)
Actual position PCS axis (real)
Actual position BCS axis (real)
Actual position MCS axis (IPO setpoints) (real)
With $AA_IM[S1] setpoints for spindles can be
evaluated. Modulo calculation is used for spindles
and rotary axes, depending on machine data
$MA_ROT_IS_MODULO and
$MA_DISPLAY_IS_MODULO.
Breaking position after external oscillation reversal
when approaching reversal point 1
Breaking position after external oscillation reversal
when approaching reversal point 2
P5: Oscillation - only 840D sl
12.6 Data lists
SINUMERIK 828D
-
-
-
SINUMERIK 828D
-
-
-
-
-
-
845