Configuring alarm outputs
1. Select and expand the SISTORE node.
2. Select and expand the Alarm Output folder.
3. Add the required alarm outputs: note that output number can be customised.
4. Select the Alarm Output node and its Node tab.
5. Set the Pulse duration in tenth of sec (Fig 24).
Fig 24
Configuring SISTORE alarm outputs
SISTORE AX
Check MM8000 and SISTORE AX Release Notes about known problems and
specific compatibility issues.
Be sure that the Usernames and Passwords, IP address and Ports are set in
Composer as in the SISTORE AX RAS software (Local Setup  Remote Site).
Do not use the SISTORE AX RAS application on the same PC as MM8000. Af-
ter using the RAS viewer, the MM8000 cannot display live video pictures any
more. To fix this, you need to launch the Init_CCTV_ENV.exe in the MM8000
Utility folder.
Do not connect simultaneously with another PC via RAS Software to the SIS-
TORE AX. When starting RAS, stop the MM8000 clients temporarily.
Only one playback per station at the time is possible, even when quad-view is
used.
SISTORE MX / MX Pro / MX NVS
Check MM8000 and SISTORE Release Notes about known problems and spe-
cific compatibility issues.
On each client station with video functions, disable the Auto-disconnect option
in the SISTORE MX RemoteView configuration (see Fig 25 below). Default set-
ting is auto-disconnect time enabled after 5 min. and causes the live video in
MM8000 to freeze when the time expires.