Encoder system connection
10.4 Sensor Module External SME25
10.4.5
Installation
①
Contact surface
Figure 10-21 Drilling pattern for installing the SME20/SME25
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is
bare, unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Fix the Sensor Module to the mounting surface. The tightening torque is 6 Nm.
10.4.6
Technical data
Table 10- 20 Technical data
6SL3055-0AA00-5HA3
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated (f
SSI/EnDat 2.1 baud rate
PE/ground connection
Weight
Degree of protection
260
Unit
V
DC
A
DC
A
DC
W
V
DC
A
DC
)
kHz
encoder
kHz
kg
Value
24 (20.4 ... 28.8)
≤ 0.15
≤ 0.25
≤ 4
5
0.35
≤ 500
100
At the housing with M4 / 1.8 Nm screw
0.31
IP67
Manual, 11/2017, 6SL3097-4AV00-0BP7
SINAMICS S120 Combi