Encoder system connection
10.3 Sensor Module External SME20
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, then it is not possible to
detect when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
Electric shock in the event of voltage flashovers at the temperature sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Use temperature sensors that comply with the specifications relating to protective
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
10.3.4

Connection example

Figure 10-14 Connection of a direct encoder system via a Sensor Module External (SME)
252
WARNING
separation.
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal
Module TM120.
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7