Figure 45: 50-Pin System Connector Pin-Outs (Conventional) - Motorola ASTRO 25 GTR 8000 Manual

Base radio
Hide thumbs Also See for ASTRO 25 GTR 8000:
Table of Contents

Advertisement

MN003286A01-E
Chapter 3: GTR 8000 Base Radio Installation
Pin No.
Signal
40
Aux Out Relay 8
N.O.
41
Aux Out Relay 9
N.O.
42
Aux Out Relay 10
N.O.
43
GND
44
GND
45
RSTAT
46
GND
47
TX DATA +
48
GND
49
PL +
50**
Gen TX +
* For detailed information on the differences between the automatic Fallback In-Cabinet Repeat and
the externally-wired In-Cabinet Repeat functions, see the Conventional Operations manual.
** It is the responsibility of the third-party vendor to ensure that the signal generated by their device is
compliant with any regulatory agency limitation imposed on the channel. This signal is not filtered or
limited by the GTR 8000 Base Radio.
Figure 45: 50–Pin System Connector Pin-Outs (Conventional)
114
Type
Function
Output
Main Standby - Antenna Re-
lay
Output
Output
GND
GND
Output
For future use
GND
GND
Input
PL(+ ) In
Input
Gen TX DATA +
Note
Form Relay A Closed When Active
Form Relay A Closed When Active
Form Relay A Closed When Active
0 Volts When Inactive / +5 Volts
when Active
Analog Signal – 600 Ohm Balanced
Analog Signal – 600 Ohm Balanced

Advertisement

Table of Contents
loading

Table of Contents