GE Energy
Familiarization
, continued
I/O Peripheral
Each D20 peripheral I/O module consists of two separate assemblies:
Module
WESDAC logic panel, for Data Acquisition and Control
Assembly
WESTERM panel, for field Termination
The logic panel contains the logic circuitry and active components. The termination
panel provides terminations for all field I/O, power, the local WESMAINT port, and
the HDLC port for the D.20 Link.
The logic board sits in a metal enclosure and plugs directly into the termination
panel. The termination panel sits on a 5.25" wide metal panel designed for flat or
rack mounting. The logic panel enclosure is faced with semi-transparent acrylic,
through which the user can monitor LED displays for various peripheral functions
and all field I/O points.
Hot-swap
The WESDAC board can be hot-swapped off the WESTERM board without
Peripherals
disconnecting the power. A module failure is indicated on the LED displays. If a unit
fails, you can unplug the failed WESDAC unit and replace it with a working unit
while the power remains on. Once the new unit is installed, the D20ME/ME II
automatically downloads the appropriate database parameters to the module to make
it operational.
Note:
General
Full
Metal Mounting
Plate
This can be done without removing power from the peripheral, hence
"hot-swap".
Installation and Operations Guide
994-0078-2.00-7
D20/D200
Acrylic Display
Cover
Terminal Blocks