D20/D200
The D20/D200 does not require any scheduled maintenance. Periodic inspection is
Maintenance
suggested to ensure that:
Unit has sustained no accidental physical damage
Airflow is not obstructed
Connectors and cables are intact and firmly attached
Fuses are intact
Battery condition is good
Servicing Tasks
Use this section of the guide for regular servicing and preventative maintenance
inspection tasks:
Locations and standard values of all fuses
How to inspect and replace batteries on the D20ME/ME II main board
D20 Power
The D20 Power Supply has one or two field-replaceable fuses.
Supply Fuses
Replaceable
Field-replaceable fuses for the standard chassis-mounted Power Supplies:
Fuses
Power
Supply
580 – 2004
580 – 2005
580 – 2006
580 - 2007
118
Fuse
Fuse Function
F1
+DC Input
F2
-DC Input
F1
+DC Input
F2
-DC Input
F1
Line/+DC Input
F2
Neutral/-DC Input
F1
Line/+DC Input
F2
Neutral/-DC Input
994-0078-2.00-7
GE Energy
Field Replaceable
Field Replaceable
Fuses
Fuses
Replacement Fuse
(¼" x 1 ¼" Time Delay)
12A / 250V
12A / 250V
12A / 250V
12A / 250V
4A / 250V
4A / 250V
4A / 250V
4A / 250V