Zero Mark Emulation (Sinamics Mode) - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.23.3

Zero mark emulation (SINAMICS mode)

The referencing mode set for the leading encoder is used to determine the zero mark
position for the zero mark emulation of the TM41.
Possible referencing modes are:
● Referencing to the zero position of the encoder
● Referencing to the zero position of the encoder with selection of the correct zero position
● Referencing to an external zero mark connected via an input terminal (CU parameter
Note
Original encoder with several zero marks
If the original encoder (leading encoder) has several zero marks/positions, an additional
condition (BERO signal) must be selected for the required zero mark.
Adjustable zero mark offset at the TM41 output
An offset of the pulse grid can be set for the the zero mark position of the encoder emulation
using p4426.
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
– Encoder zero mark of an incremental encoder
– Zero passage of the singleturn position of an absolute encoder
– Pole pitch of the resolver
using a BERO switching signal (CU parameter p0493)
p0495)
Basic functions
7.23 Terminal Module 41
365

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents