Siemens SINAMICS S120 Function Manual page 785

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 12- 2
Parameter
p0130
p0180
p0186[0...1]
p0820
p0821 to p0824 0
p0826[0...1]
p0827[0...1]
r0830.0 and r0830.1
p0831[0...1]
p0833.0..2
p2155.0...1
Drive functions
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4
Figure 12-6
Example: star-delta changeover
Settings for the example
Settings
2
2
0, 1
p2197.2
0
0; 0
0, 1
Digital outputs,
contactors
Digital inputs, auxiliary
contacts
0, 0, 0
Changeover speed
Remark
Configure two MDS.
Configure two DDS.
The MDS are assigned to the DDS.
Changeover to delta connection after speed in
p2155 is exceeded.
Identical numbers signify the same thermal
model.
Assigning the bit from r0830 to the MDS. If
p0827[0] = 1, for example, bit r0830.1 is set when
MDS0 is selected via DDS0.
The digital outputs for the contactors are assigned
to the bits.
The digital inputs for the feedback signal of the
motor contactors are assigned.
The drive controls the contactor circuit and pulse
inhibition. Parking bit (Gn_ZSW14) is set.
Sets the speed at which the circuit is to be
changed over to delta.
Note:
Using p2140, you can define an additional
hysteresis for the changeover (refer to function
diagram 8010 in the SINAMICS S120/150 List
Manual).
Applications
12.5 Description
785