Monitoring and protective functions
8.5 Thermal motor protection
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Thermal motor model 1
• r0034
• p0318[0...n]
• p0605[0...n]
• p0611[0...n]
• p0612[0...n]
• p0615[0...n]
Thermal motor model 2
• p0344[0...n]
• p0612[0...n]
• p0617[0...n]
• p0618[0...n]
• p0619[0...n]
• p0625[0...n]
• p0626[0...n]
• p0627[0...n]
• p0628[0...n]
• r0630[0...n]
• r0631[0...n]
• r0632[0...n]
• r0633[0...n]
Thermal motor model 3
• p0612[0...n]
• r0630[0...n]
• r0631[0...n]
• r0632[0...n]
• r0633[0...n]
538
CO: Motor utilization
Motor stall current
Mot_temp_mod 1/2 threshold
I2t motor model thermal time constant
Mot_temp_mod activation
Mot_temp_mod 1 (I2t) fault threshold
Motor weight
Mot_temp_mod activation
Stator thermally relevant iron component
Stator thermally relevant copper component
Rotor thermally relevant mass
Motor ambient temperature
Motor overtemperature, stator iron
Motor overtemperature, stator winding
Motor overtemperature, rotor winding
Mot_temp_mod ambient temperature
Mot_temp_mod stator iron temperature
Mot_temp_mod stator winding temperature
Mot_temp_mod rotor temperature
Mot_temp_mod activation
Mot_temp_mod ambient temperature
Mot_temp_mod stator iron temperature
Mot_temp_mod stator winding temperature
Mot_temp_mod rotor temperature