08.96
4049
Display selection not poss.
Explanation:
Measurement result display cannot be selected, because selection is
possibly carried out by the PLC.
Access to PLC data disabled by @ (PLC MD 6026.2).
4100
No D number active
Explanation:
No D number programmed in the program.
Remedy:
Enter D number in part program.
4121
Spindle not in tol. range
Explanation:
The spindle position is monitored in the cycle as soon as the function
"M19 with axis motion" is activated.
The measuring cycle is not continued, until the spindle has been in the
exact stop for M19 for approx. 0.2 seconds.
Remedy:
This alarm is output, if this position is not reached within 6 seconds.
4180
Option not available
Remedy:
Retrofit measurement option (Service)
4200
Check definition R(Nxxxx)
Explanation:
Defining parameter incorrectly defined.
Block number N = R parameter number.
Remedy:
Correct part program.
4219
Call cycle again
Explanation:
Measurement variant selected for JOG measuring not clearly defined.
Remedy:
Select measurement variant again after RESET.
©