Install Adapter Set As 2/R-1200, As 2/R-2200 - Bosch Rexroth LU 2 Assembly Instructions Manual

Automatic lubrication unit
Table of Contents

Advertisement

1.
Install the hose
connector (C) in the
lubricating pin (A).
2.
Remove the side cover of
the drive head.
3.
Insert the lubrication
pin (A) in the correct
position in the bore of
the drive head.
4.
Secure the lubrication pin
with the lock washer (B).
5.
Install 2 O-rings (D) on
the lubrication pin (A) so
that they snap into the
grooves (X).
6.
Install the lubrication line.
7.
Install the side cover of
the drive head.
8.5.8

Install adapter Set AS 2/R-1200, AS 2/R-2200

4x
SW10
M
= 10Nm
D
Fig. 17:
Install adapter Set AS 2/R-1200, AS 2/R-2200
Please note:
• Only use 2 equal lubricant pins (do not mix adapter sets).
Different lubricating pins cause unequal distribution through an uneven
fl ow resistance.
• The difference in length of the lubrication lines should be < 20 mm.
Different lubricating line lengths cause unequal lubrication distribution through
an uneven fl ow resistance.
• The lubrication line must always be placed lower than the lubricating pin,
otherwise the lubrication line runs empty (uncontrolled oil spillage, bubbles are
formed in the hoses)
• Fill the lubrication line before commissioning, e.g. by repeatedly pressing the
lubricating device (button in the PLC control) or using the special delivery PURGE
(see page 23), until lubrication comes out of the lubrication pin.