8 Installation

8.1 Unpacking

Lift the product from its packaging.
Dispose of the packaging material in accordance with the national laws of
your country.

8.2 Installation requirements

During installation the ambient conditions specifi ed in the technical data
(see page 53) must be maintained.
8.2.1

Installation position

Install the product level and plumb at right angles and parallel to the axis.
This ensures proper functioning and prevents premature wear.
8.2.2

Mounting with T-bolts

• Mount the transfer systems TS 1, TS 2plus, TS 2pv, TS 4plus, TS 5 and the chain
conveyor systems VarioFlow and VarioFlow S with T-head bolt and collar nut.
• Make sure the T-bolt is in the correct position when inserting and tightening in the slot.
The notch at the end of the bolt indicates the orientation of the T-bolt.
1 = T-bolt insertion position in the slot.
2 = T-bolt clamping position in the slot.
Tightening torque: 25 Nm (M8).

8.3 Required tools

• Hex head cap screw SW13.
• Hex socket head cap screw SW3, SW4, SW5, SW6.
• Cross recess screwdriver PZ2
• Rubber mallet
• Spirit level
• Expanding pliers
• Cutter to shorten the lubrication line.
Installation
3 842 358 814/2017-01, MIT: LU 2, Bosch Rexroth AG
27/54

Hide quick links: