The following types of system component are available:
System component
Central Interface Module
(CIM)
I/O module
Power Output Module
(POM)
Expansion module
Features
● Modular (centralized) and compact (distributed) configurations possible
● Communication via PROFINET/PROFIBUS
● Parameter assignment, commissioning, visualization and diagnostics via
Siemens TIA Portal
● Support of configuration and commissioning of the PROFINET network with PRONETA
● Integrated diagnostics and monitoring functions
● Control modes: Half-wave control, soft start and phase control
● Line voltage compensation for smoothing line voltage fluctuations integrated
● Only one 24 V power supply required for up to 8 POM4320 or 6 POM4320 Highend
● Slot for one I/O module (PM)
● Expansion module (optional) with 24 V power supply for operation of an additional
2 x 8 POM4320 or 2 x 6 POM4320 Highend
SIPLUS HCS4300 PROFINET/PROFIBUS DP
Operating Instructions, 10/2019, A5E35452705A/005
Version
CIM4310 PROFINET
•
CIM4310 PROFIBUS
•
PM4000 DI/DO
•
PM4000 U/I
•
PM4000 Temperature
•
POM4320 busbar mounting
•
POM4320 panel mounting
•
POM4320 Highend busbar
•
mounting
POM4320 Highend for panel
•
mounting
EM4315
•
System overview
Description
A maximum of 8 POM4320 or 6
POM4320 Highend can be operated at
a CIM.
8 digital outputs and 8 configurable
inputs/outputs.
Inputs for measuring line voltage and
line current.
4 analog inputs for 0 mA to 20 mA and
4 measuring inputs for temperature
9 power outputs with diagnostic func-
tion and fault indication per channel.
6 power outputs with diagnostics and
error display per channel.
Enables operation of up to 8 additional
POM4320 or 6 POM4320 Highend.
3.2 Features
17