Communications
10.2 Acyclic data exchange
Data record 2 "POM4320 Highend configuration data"
The data record describes a function of the POM4320 Highend and addresses a POM.
Byte
0, 1
2, 3
4, 5
6, 7
8, 9
10, 11
12, 13
14, 15
16, 17
18, 19
20, 21
22, 23
24
25
Definition is via an array [1 to 6] with two elements of the type "Integer". The data record
corresponds to the information from the configuration (Page 86) and allows overwriting of the
configuration during operation.
The data record is answered with errors if no POM4320 Highend is addressed.
Data record 50 "Direct switching of the outputs"
The data record describes an HCS function and addresses the HCS.
Byte
0 to 25
This data record can be used to disable the time scale with which the setpoints are activated
in the HCS (see section Half-wave control (Page 106)).
The operation process cannot be undone.
Definition is via an array [0 to 25] of the char type. The introductory text must correspond
exactly to the specification; otherwise, the data record is rejected with an error and is not
executed.
136
Bit
Meaning
-
Total power for channel 1
-
Maximum permitted deviation from total power for channel 1
-
Total power for channel 2
-
Maximum permitted deviation from total power for channel 2
-
Total power for channel 3
-
Maximum permitted deviation from total power for channel 3
-
Total power for channel 4
-
Maximum permitted deviation from total power for channel 4
-
Total power for channel 5
-
Maximum permitted deviation from total power for channel 5
-
Total power for channel 6
-
Maximum permitted deviation from total power for channel 6
0
Parallel connection of loads at channel 1
0: No (default)
1: Yes
1
Parallel connection of loads at channel 2
2
Parallel connection of loads at channel 3
3
Parallel connection of loads at channel 4
4
Parallel connection of loads at channel 5
5
Parallel connection of loads at channel 6
0
Meaning