Technical specifications
13.4 Technical specifications for I/O module
Article number
Degree and class of protection
IP degree of protection
Standards, approvals, certificates
Reference designation according to DIN EN
81346-2
Ambient conditions
Ambient temperature during operation
•
•
Ambient temperature during stor-
age/transportation
•
•
•
•
Air pressure acc. to IEC 60068-2-13
•
•
•
•
Altitude during operation relating to sea level
•
Relative humidity
•
•
Vibrations
•
•
Shock testing
•
•
Dimensions
Width
Height
Depth
184
min.
max.
Storage, min.
Storage, max.
Transportation, min.
Transportation, max.
Operation, min.
Operation, max.
Storage, min.
Storage, max.
Installation altitude above sea level, max.
Operation at 25 ℃, max.
Operation at 50 ℃, max.
Vibration resistance during operation acc.
to IEC 60068-2-6
Vibration resistance during storage acc. to
IEC 60068-2-6
Shock resistance during operation acc. to
IEC 60068-2-27
Shock resistance during storage acc. to
IEC 60068-2-29
6BK1900-0BA00-0AA0
IP20
K
0 °C
55 °C
-25 °C
70 °C
-25 °C
70 °C
860 hPa
1 080 hPa
660 hPa
1 080 hPa
2 000 m
95 %
50 %; 95 % at 25 °C, decreasing linearly to 50 %
at 50 °C
10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1 g
5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1 g
15 g / 11 ms / 3 shocks/axis
25 g / 6 ms / 1 000 shocks/axis
27 mm
141 mm
110 mm
SIPLUS HCS4300 PROFINET/PROFIBUS DP
Operating Instructions, 10/2019, A5E35452705A/005