10.4 Commissioning measuring cycles for HMI-Advanced PCU50 powerline as of SW 06.03.19. and/or
SW 06.04.10 and HMI-Advanced PCU50 Solutionline
10.4.4
Step 3 - activate entry softkeys "Measure turning" and "Measure milling" for
measuring cycle support
Use the Enter key to open AEDITOR.COM in the "Services" operating area in the "Standard
cycles" directory.
The semicolons before the following lines must be deleted:
;HS14=($83530,,se1)
;PRESS(HS14)
;LS("D_mess","MZ_SKL.COM",1)
;END_PRESS
;HS15=($83531,,se1)
;PRESS(HS15)
;LS("F_mess","MZ_SKL.COM",1)
;END_PRESS
10.4.5
Step 4 - activate softkey "Measuring cycles" in the "Commissioning" area
Use the Enter key to open STARTUP.COM in the "Services" operating area in the "Standard
cycles" directory and delete the semicolons in front of the following lines:
;HS15=($83070,,se1)
;PRESS(HS15)
;If SYSTEM ==1
;LS("Messz","mz_einst.com")
;Else
;LS("Messz1","mz_einst.com")
;EndIf
;END_PRESS
10.4.6
Step 5 - activate entry softkeys "Measure workpiece" and "Measure tool" for
measuring in JOG in the machine's "JOG" area
Use the Enter key to open MA_JOG.COM in the "Services" operating area in the "Standard
cycles" directory.
The semicolons before the following lines must be deleted:
;HS4=($83358,ac7,se1)
;PRESS(HS4)
;LM("Messen1","jog_meas.com")
;END_PRESS
;HS5=($83359,ac7,se1)
;PRESS(HS5)
;LM("Messen2","jog_meas.com")
;END_PRESS
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Start-up (hardware)
10-13