Miscellaneous functions
7.2 Measuring cycle support in the program editor (up to measuring cycles SW 5.4)
Parameter
7.2.4.5
Calibration in groove - CYCLE_973
With CYCLE_973
Softkeys
CYCLE973 can be parameterized to calibrate a reference groove.
Parameter
Parameter
_SETVAL
_MA
_MD
_CALNUM
_PRNUM
7.2.4.6
Calibration in hole - CYCLE_976
With CYCLE_976
Softkeys
CYCLE976 can be parameterized to calibrate a hole.
Parameter
Parameter
_SETVAL
7-16
Type
Value
Meaning
10000: Calibrating in the 3rd axis with calculation of probe
length
→
Type
Value
Meaning
REAL
Setpoint
INTEGER
Selection: Positional deviation
0...without / 1...with specification of positional deviation
INTEGER
Selection: Number of axes
Number of axes to be calibrated, 1, 2
INTEGER
Selection: Ball calculation
0...without / 1...with calculation of probe ball diameter
INTEGER
>0
Number of measuring axis 1, 2
INTEGER
≥0
Determines measuring direction
0...in positive direction / 1...in negative direction
INTEGER
≥0
Selection of calibration groove with number
INTEGER
>0
Probe number
→
Type
Value
Meaning
REAL
Setpoint
INTEGER
Selection: Angular position
0...Paraxial calibration/1...calibration at an angle
INTEGER
Selection: Positional deviation
0...without / 1...with specification of positional deviation
INTEGER
Selection: Number of axes
Number of axes to be calibrated, 1, 2 or 4
INTEGER
Selection: Ball calculation
0...without / 1...with calculation of probe ball diameter
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring cycles