Instructions for fitting connectors, attachments and devices
2.4 Optical networks
Procedure
A stripping pliers
B Kevlar scissors
C cleave tool
D fiber container
E card cleaner
F microscope
3. Pull off the outer jacket.
6. Position the ø 1 mm opening of the
stripping pliers approximately 80
mm from the end of the core.
66
a anti-kink sleeve
b union nut
c buffer and Kevlar clamp
d body of connector
e ferrules
f SC RJ housing
g dust protection
4. Cut off the Kevlar yarn and fleece
wrapping with the Kevlar scissors.
7. Cut into the core jacket and pull the
jacket partly off without skewing.
1. Remove the outer jacket using a
stripping tool.
2. Set the cutting depth of the stripping
tool so that the inner cores cannot
be damaged.
5. Cut off the blind elements (gray)
and the support element (white)
with the side cutter.
8. Remove the loose core sleeve with
your hand.
Passive network components