Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
Procedure
1. Remove the locking screw of the
insert. (1.)
Pull the insert forward as far as the
limit stop. (2.)
4. Strip the approx. 55 mm of the
jacket of the IE Hybrid Cable 2x2 +
4x0.34.
Shorten the shield of the data wires
by approx. 5 to maximum 20 mm.
Cut off the dummy cores.
Spread the wires according to the
color markings in the figure above.
Cut all the wires in a straight line to
leave 48 mm to the cable jacket.
44
2. Now release the two cover screws
that are now accessible
5. Insert the wires pair by pair into the
wire channels of the insulation
piercing terminals according to the
color codes in the picture on the
left.
The color codes on the terminal
block of the modular outlet have no
meaning for the hybrid cable!
The ends of the wires must be
visible in the last viewing window of
the terminal block and must meet
the back panel of the terminal block!
3. Lift up the upper part of the IE FC
RJ-45 Modular Outlet. (4.)
Lift up the 4 terminals of the terminal
block. (5.)
6. Secure the wires in position by
pressing down the terminals as far
as the limit stop.
Repeat these steps until all four
pairs or wires are connected.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01