7. When the code type is GS1 DataBar Stacked CC-A/GS1DataBar Limited CC-A and specify its 2D side
settings
Name
(> Name in LP-400/V)
Object No.
(> Bar code No.)
System reserved
value
(Area No.)
Code type
2D side human
readable text
Row height for 2D
side
Number of rows for
2D side
Number of columns
for 2D side
Separator height to
module width ratio
Horizontal quiet zone
to module width ratio
for 2D side
System reserved
value
(> Error correction
level)
2D side laser power
correction
2D side scan speed
correction
2D side pulse cycle
correction *
Total data length
* Only for LP-RF series and LP-RV series.
98
Data length
Data contents
[byte]
1
"0"–"7": Object No. 1100 to 1107
1
"0"–"9", "A"–"F"
"41": GS1 DataBar Stacked CC-A
2
"43": GS1 DataBar Limited CC-A
"1": OFF
1
"3": ON
5
"0.050"–"9.999" [mm]
GS1 DataBar Stacked CC-A
"00": Auto (minimize setting)
"05"–"10", "12" [rows]
2
GS1 DataBar Limited CC-A
"00": Auto (minimize setting)
"04"–"08" [rows]
2
"00": Auto
4
"00.0"–"10.0"
4
"00.0"–"20.0"
1
"0"
3
"000"–"999" [%]
3
"001"–"999" [%]
(3)
"001"–"999" [%]
29
The data length is fixed.
or
• LP-GS/LP-RC series: 29-byte
32
• LP-RF/LP-RV series: 32-byte
ME-LP-GS-SR-COMP-3
Remarks
This value does not affect the settings
anymore.
For the composite codes, this setting is
applied to both 1D and 2D side.
• Specifies the height for one row of the
2D side.
• In Laser Marker NAVI smart, this setting
is converted to the ratio to the module
width of 1D side and displayed as "Row
height to module width ratio for 2D side".
"00": Auto sets the minimum value
depending on the code data settings.
• Specifies the height of the separator
placed between 1D and 2D.
• Specifies the ratio to the module width
of 1D side.
• Specifies the quiet zone width of the 2D
side.
• Specifies the ratio to the module width
of 1D side.
• The correction ratio is calculated using
the value set at the laser settings as
100%.
• At LP-400/V compatible command
mode, the same correction values are
applied to the separator.