Panasonic LP-GS Series Serial Communication Command Manual page 153

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

ERROR
CODE
E505 - E509
Safety functions (INTERLOCK, LASER STOP,
E550 - E560
etc.) were activated during marking preparation.
E572
E520 - E522
E570
File data or system data were not saved
successfully, because the laser marker was
turned off while saving data.
Unable to read the file data.
E530 - E542
E571
*1 : If the error persists after restart of the laser marker, contact our sales office or representatives.
*2 : Error that may occur for LP-GS series only.
*3 : Error that may occur for LP-RC series only.
*4 : Error that may occur for LP-RF series and LP-RV series only.
Description
ME-LP-GS-SR-COMP-3
Measures *1
• Reset the alarm for LASER STOP IN or
INTERLOCK of the I/O terminal block or Stop
laser button of Laser Marker NAVI smart
software.
• Check if the signal lines are effected by noise.
• Overwrite the data again to the selected file
number.
• Do not turn off the laser marker while saving
the settings.
• Restore the backup file saved before to the
laser marker.
• Do not turn off the laser marker while saving
the settings.