3.3 S7 communication

3.3
S7 communication
S7 communication allows the following:
● The inverter is controlled from a SIMATIC panel, also without control system by directly
accessing the inverter via PROFIBUS or PROFINET.
● Remote maintenance by accessing the inverter with STARTER or Startdrive across
network boundaries.
In the following example, we describe how you can switch the inverter on and off through a
SIMATIC panel, how to specify a setpoint and be shown the actual value on the panel.
You can find a description about accessing inverters across network boundaries in the
application document 25339612.
3.3.1

Directly accessing a SINAMICS G120 converter from a SIMATIC panel

Example of direct access to the inverter via a SIMATIC panel
You want to use the SIMATIC panel to do the following:
● Switch the inverter on and off
● Enter a setpoint
● Display the actual value and status
Conditions
You have installed the following software packages on your computer and made the
following settings:
● WINCCflex 2008 SP1 or higher
● STARTER plus SSP for 4.7 or higher
● You have configured the inverter in STARTER
● Inverter and panel are connected with one another via PROFIBUS or PROFINET.
● The same baud rates are set in the inverter and in the panel.
● The bus address configured in WinCC flexible matches the bus address of the inverter.