CORRECTIVE MAINTENANCE
Current Status
This condition is not an alarm. The message indicates the current state of PTP logical
ports.
Early Warning
This condition indicates that the system detects degradation of radio signals. (Early
Warning threshold detection.)
Procedure 5-5
1.
2.
Equipment Start-up Status
This condition is not an alarm. The system reports that the equipment starts up, and
the cause to start up or reboot.
ETH LF
This condition indicates that the 10G Ethernet Port on the local NE fails.
Procedure 5-6
1.
2.
3.
iPASOLINK EX Advanced: O
Launch the WebLCT.
Display the
Current Metering
If the value is appropriate, replace the equipment.
If the value is inappropriate, proceed with the flowchart:
Shooting Flow
.
This step ends the procedure.
Check that the Ethernet Cable connected to the target port is appropriately
connected.
Retrieve the
Current Status
Is
alarm cleared?
ETH LF
This step ends the procedure.
YES:
Replace the cable, then proceed to the next step.
NO:
& M
PERATION
AINTENANCE
to check
.
RX Level
, and check if the
ETH LF
5-25
Equipment
MODEM
5.4 Trouble
Equipment
alarm is cleared.
GGS-000548-01E
ETH