Detailed description
2.7 Actions in synchronized actions
2.7.11
Starting/stopping axes (MOV)
Function
An axis can be traversed without specifying an end position via the
traverses so long in the specified direction until it is stopped or another traversing direction is
specified by a
Application: Endlessly rotating rotary axes
Syntax
MOV[<axis>] = <direction>
Meaning
MOV
<axis>
<Direction>
Note
Indexing axis
If an indexing axis is stopped, it stops at the next indexing position.
Technology cycle
The
See also
Axial feedrate (FA) (Page 91)
90
command.
MOV
command must not be used in technology cycles.
MOV
Start traversing motion
Channel axis identifier
Type: AXIS
Traversing direction
Type: INT
Range of values:
> 0: Positive traversing direction (default: +1)
<Direction>
< 0: Negative traversing direction (default: -1)
<Direction>
= 0: Stop
<Direction>
command. The axis
MOV
Function Manual, 07/2012, 6FC5397-5BP40-3BA0
Synchronized actions