Bosch C60 Manual page 88

Hide thumbs Also See for C60:
Table of Contents

Advertisement

12 | Recording and Telemetry
12.5.3 Troubleshooting
88 / 108
Removing the USB device
Always power off the system before unplugging the USB device!
If the USB device is unplugged while recording is active, parts of the measurement data
may be missing.
If the USB device is unplugged and re-inserted for < 4 s while the C 60 is powered up, the
C 60 still records data.
If the USB device is unplugged and re-inserted for > 4 s while the C 60 is powered up or a
different USB device is plugged in, the C 60 restarts. In this case, the C 60 is not opera-
tional for 1.5 s.
When no data on the USB device is recorded:
Configure the measurement label usb_mediastate on a RaceCon measurement view or
on a C 60 display page.
The value of usb_mediastate reflects the operating condition of the USB bus:
State
0: Wait: Device not found The USB device is not found (also: waiting for re-plug stick).
1: Wait: Device detected
2: Ok: Media installed
3: Stop: Device unplugged The USB device has been removed.
4: Ok: Media access
5: Error: Media error
6: Error: Media corrupt
Data Logger C 60
Description
No USB device inserted.
USB device is defect.
No electrical connection or wiring harness problem.
USB software upgrade not activated (Purchase of unlock code
needed).
An USB device is found, but not yet installed.
The USB device is found and is operational (idle).
This does not imply that recording data is written!
The C 60 performs a restart when an USB device is re-plugged
in.
Data is currently read from/written to the USB device.
The communication to the USB device broke down.
The USB device is defect.
The USB device is not supported by C 60.
The USB device is not in valid BFS format.
(Hint: Re-format the USB device in RaceCon.)