10 | Analog and Frequency Inputs
10.8.4 Configuring a multipoint adjustment
60 / 108
9.
Click 'OK' when done.
The channel is inserted into the C 60 Project Tree.
Available measurements for channel:
Measurement label
raw_name
raw_name_fi
name
name_fi
Example: Measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
1.
Click on 'Measurement Sources' in the Toolbox.
2.
Expand the list of 'I/O Channels' by clicking on '+' in the C 60 Project Tree.
3.
Drag the 'Multipoint Adjustment' analog signal source from the Toolbox and drop it
on the desired analog input channel in the C 60 Project Tree.
4.
A 'Multipoint Adjustment Wizard' opens.
5.
To activate the internal pullup-resistor, check the box.
The internal pullup-resistor is used to get a 5 V signal at the analog channel of the C
60.
It allows you to use a push-button.
The fixed value of the internal pullup-resistor is 3010 ohm. If using an additional ex-
ternal pullup-resistor, set up the overall resistance.
Data Logger C 60
Function
mV value of sensor
filtered mV value of sensor
physical value of sensor
filtered physical value
Bosch Motorsport